H1: Laser Alignment Protocol for Optimal ROTARY VALVE Performance
5-Step Process
Clean Flange Faces (Ra <3.2μm)
Install Dial Indicators on Drive Shaft
Adjust Motor Shim Packs (0.05mm Precision)
Verify Runout <0.1mm TIR
Conduct Hot Alignment Check After 24 Hours