H1: 3 Professional Techniques to Validate ROTARY VALVE Sealing
Bubble Test: 0.5 bar Air Pressure + Soap Solution
Pressure Decay: <0.1 bar Drop in 10 Minutes (ISO 5208)
Helium Mass Spectrometry: Sensitivity 1×10⁻⁶ mbar·L/s